An investigation to determine the fraction of total fission energy absorbed by the organic coolant in a 555-Mw OMR operating at full power with a bulk coolant temperature of 585 deg F is described. The calculated fraction was 4.00%. (J.R.D.)
U.S. Atomic Energy Commission depository collection.
Note
NSA number: NSA-14-007888 OSTI Identifier 4194871 Research organization: Atomics International Div., North American Aviation, Inc., Canoga Park, Calif.