Actions for Cold trap requirements for PHTS and IHTS sodium purification
Cold trap requirements for PHTS and IHTS sodium purification
- Author
- Sletten, H. L.
- Published
- United States : [publisher not identified], 1974.
Springfield, Va. : National Technical Information Service, [approximately 1974] - Physical Description
- microfiche : negative ; 11 x 15 cm
- Summary
- Cold trap requirements for the Primary Heat Transfer System (PHTS) and the Intermediate Heat Transfer System (IHTS) are defined. The bases for these requirements are (1) maintaining concentrations of oxygen and hydrogen within given limits, (2) controlling the transport of tritium by coprecipitating it in cold traps together with hydrogen, and (3) providing the necessary volume capacity for collecting impurities. It is concluded that the 60 gpm, FFTF Type I, NaK cooled, cold trap will satisfy the PHTS requirements. For each of the IHTS loops a single, 60 gpm, cold trap is required; and an aircooled trap similar to the FFTF Type I design except for a 3-foot longer crystallizer section has been chosen for this service.
- Report Numbers
- DOE/TIC-11040; TI-099-811-013
- Other Subject(s)
- 21 specific nuclear reactors and associated plants
- 210500 - power reactors, breeding
- Breeder reactors
- Clinch river breeder reactor
- Cold traps
- Condensers
- Cooling systems
- Epithermal reactors
- Fast reactors
- Fbr type reactors
- Liquid metal cooled reactors
- Lmfbr type reactors
- Performance
- Power reactors
- Primary coolant circuits
- Reactor components
- Reactor cooling systems
- Reactors
- Secondary coolant circuits
- Sodium cooled reactors
- Specifications
- Traps
- Vapor condensers
- Collection
- NTIS collection.
- Note
- DOE contract number: EY-76-C-03-0824-025
OSTI Identifier 5622740
Research organization: Atomics International Div., Canoga Park, CA (USA).
View MARC record | catkey: 45332939