Reactor physics calculations have been performed to investigate the feasibility of conducting loss of coolant (LOCA) experiments that will require steady state operation with the present Power Burst Facility (PBF) reactor core configuration. It was determined that sufficient excess reactivity would be available for 48 hour irradiation of a 16-pin LOCA test cluster at a PBF core power of 30 MW. It was also determined that shutdown requirements could be met with the LOCA test in place and that no additional reactivity shimming would be necessary. A description of these calculations is given.
U.S. Atomic Energy Commission depository collection.
Note