Actions for Validation of plant-wide data and fault identification at steady-state
Validation of plant-wide data and fault identification at steady-state
- Author
- Tzanos, C. P.
- Published
- United States : [publisher not identified], 1984
Springfield, Va.: National Technical Information Service, [approximately 1984] - Physical Description
- microfiche : negative ; 11 x 15 cm
- Summary
- This paper presents a methodology of data validation and fault identification, based on analytic redundancy, for steady-state plant operation. This work differs from previously reported work on analytic redundancy in that validation of all the main parameters of the plant heat-transport loops is sought by using plant-wide instrument information. An LMFBR plant is used as a reference, and validation of the following plant parameters is considered: reactor power (Q), reactor inlet and outlet coolant temperatures (T/sub IC/ and T/sub OC/, respectively), intermediate heat exchanger (IHX) inlet and outlet secondary coolant temperatures (T/sub IS/, T/sub OS/), steam generator feedwater temperature (T/sub w/), steam temperature (T/sub S/) and pressure (P/sub s/) as well as primary, intermediate, and feedwater flows (G/sub p/, G/sub I/, G/sub w/).
- Report Numbers
- DE84011735; CONF-840286-1
- Other Subject(s)
- 21 specific nuclear reactors and associated plants
- 210500 - power reactors, breeding
- 22 general studies of nuclear reactors
- 220400 - nuclear reactor technology- control systems
- Boilers
- Errors
- Failures
- Feedwater
- Heat exchangers
- Hydrogen compounds
- Oxygen compounds
- Power
- Reactor instrumentation
- Steam generators
- Temperature measurement
- Testing
- Validation
- Vapor generators
- Water
- Collection
- NTIS collection.
- Note
- DOE contract number: W-31-109-ENG-38