Actions for Long term ice condenser containment code : LOTIC code. [PWR].
Long term ice condenser containment code : LOTIC code. [PWR].
- Author
- Grimm, N. P.
- Published
- United States : [publisher not identified], 1976.
[Oak Ridge, Tennessee] : [U.S. Atomic Energy Commission], 1976. - Physical Description
- microfiche : negative ; 11 x 15 cm
- Additional Creators
- Colenbrander, H. G. C.
- Summary
- An analytical model is presented for the calculation of ice melt and long-term pressure transients in the ice condenser reactor containment after a loss-of-coolant accident. The method applies conservation equations to control volumes used to simulate spatial variation. The control volumes represent the functionally distinct compartments of the ice condenser containment. Uniform pressure and saturated steam conditions are assumed throughout the containment in order to reduce the computing time for a given problem. Several required quantities are assumptions based on conclusions derived from Ice Condenser Test Facility test results. The code is flexible enough to analyze the effectiveness of the engineered safeguard systems, including internal and external sprays and a sump water recirculation cooling system. Temperature gradients in, and heat absorption by, the containment structure are also considered.
- Report Numbers
- WCAP-8355-A
- Other Subject(s)
- 21 specific nuclear reactors and associated plants
- 210200 - power reactors, nonbreeding, light-water moderated, nonboiling water cooled
- 22 general studies of nuclear reactors
- 220900 - nuclear reactor technology- reactor safety
- Accidents
- Computer codes
- Condensers
- Containment systems
- Containment
- Engineered safety systems
- Ice condensers
- L codes
- Loss of coolant
- Mathematical models
- Performance
- Pwr type reactors
- Reactor accidents
- Reactor safety
- Reactors
- Safety
- Steam condensers
- Vapor condensers
- Water cooled reactors
- Water moderated reactors
- Collection
- U.S. Atomic Energy Commission depository collection.
- Note
- OSTI Identifier 7274418
Research organization: Westinghouse Electric Corp., Pittsburgh, Pa. (USA). PWR Systems Div.
View MARC record | catkey: 47680071